Some of the tests are done at the factory during the manufacturing process. Power transformer testing power transformer factory test using ieee standards waldemar ziomek cg power systems canada ieee training, houston, texas, oct. Power factor testing of power and distribution transformers. Common electrical tests on power transformers omicron.
Tm 5686 power transformer maintenance and acceptance. Field testing of fluidfilled power transformers, regulators, and reactors. Testing of current transformers, voltage transformers or auxiliary transformers internal to the power transformer are not included in this swp. During the induced ac voltage test the transformer under test is a linear, mostly ohmiccapacitive load. The required test power depends on the power and voltage rating of the transformers under test and the specific design as well as on the tests to be performed. In this book we have laid down important aspects on transformer. C electrical power from one voltage to another voltage keeping the frequency same by electromagnetic induction discover the worlds research 16. Pdf transformer testing type test and routine test of.
Vector group test of power transformer electrical4u. Smart test set for sweep frequency response analysis. C electrical power from one voltage to another voltage keeping the frequency same by. Testing procedures for power transformer ms excel spreadsheet. Power transformers are the central hub in the field of energy distribution and transmission. It is not a complete stepbystep procedure for performing tests and is not replacing the user manual for the actual instrument. Page 1 of 14 standard work practice sp0504 ver 4 ergon energy corporation limited abn 50. Co 2 emissions requirements from eu regulations, iec ieee on both the actual losses andmeasurement accuracy conclusion 22 transformer loss measurement systems need calibration proven, validated accuracy test is a collection of physical, electrical and chemical transformer oil testing methods. Wait until 24 hours after completion of oil filling for power factor testing. The power transformer testing fat test is performed after completion of the assembly at the manufacturing shop. Power transformer testing procedures and schemes eep.
Transformer testing type tests and routine tests of. Next, attach the leads of your dmm to the input lines. Impedance dc winding resistance megger and power factor windings, bushing and arrestors. Mainly two types of transformer are done by manufacturer before dispatching the transformer mainly 1 type test of transformer and 2 routine test. So transformer ratio test is an essential type test of transformer.
Theory of transformer tft testing procedure safety prior to performing the throughfault test, it is important that all safety. Power transformer through fault test morteza talebi, power grid engineering yigitcan undug, electric power systems. Just be certain to disconnect the transformer from the circuit before testing to avoid the risk of serious injury. The priciples of routine, type and special tests are however. Trafositetesting mobile highvoltage test system for onsite testing of power transformers flv english flv movie considerations for the design, manufacture, and retrofilling of power transformers with high fire point, biodegradable ester fluids english pdf technical publication. This test also performed as a routine test of transformer. The transformer is probably one of the most useful electrical devices ever invented.
A megohmmeter megger insulation resistance test set, transformer turns ratio test set, power factor tet set, liquid dielectric test set, dew point analyzer, oxy. Testing power transformers test procedures and equipment used for the testing of large power transformers at abb oy, power transformer, vaasa works are dealt with in the following sections. In addition some other tests are also carried out by the consumer at site before commissioning and also. Inspect physical and mechanical condition including evidence of moisture and corona. Transformer insulating fluids testing the purpose of a power transformer is to alter the voltage from that of a distribution rating, to a lower utilization level. Power transformers built for reliability and efficiency power transformers. In a transformer continuity test, you disconnect the transformer from power and check resistance in both the input and output coils using the ohmmeter function. Regularly performing a range of standard electrical tests has proven an effective way to gain a reliable insight into the operating condition of your transformers and can extend their lifespan. Pdf transformer is a static device which transforms a. This guide explains the many types of transformer and the power factor test procedures for each one. The measuring equipment differens from those explained herein. Vector group test of transformerthe vector group of transformer is an essential property for successful parallel operation of transformers. The installation and testing of the transformer verifies its condition at the time it is ready for. Understanding the value of electrical testing for power.
There are various test required on transformer to conform performance of transformer. Power transformer testing procedures and schemes photo credit. Depending on the startup procedure, any of the following items may be rewired. It is important to understand the need for and value of comprehensive testing of power transformers. Transformer testing has developed considerably over the past years.
Oil tests in the shop or laboratory would be carried out at room temperature 20o c. These tests include dielectric breakdown, power factor, inter. Testing power transformers highvoltage transformers are some of the most important and expensive pieces of equipment required for operating a power system. White shermco industries introduction drytype transformers have more and more common, especially with their use at wind farm sites. As such, their condition is critical for reliable, faultfree operation. Ensure that all equipment to be tested is properly grounded and treat all highvoltage power equipment as energized until proven otherwise by using the proper lockouttagout procedures. Steel itself is a conductor, and changing lines of magnetic flux also induce a voltage and current in this conductor.
Before conducting a transformer winding resistance test, it is important to observe all safety warnings and take proper precautions. One must assure that the test cell is clean and it is a wise precaution to bleed the sampling tube to assure a representative sample. Transformers experience power loss due to load resistance, which you can test with an ohmmeter by touching the meters red and black pins to opposite ends of the transformers wiring. So for ensuring proper performance of electrical power transformer, voltage and turn ratio test of transformer one of the important tests. It evolved from the simple gonogo verdict into a sophisticated segment within transformer manufacturing. Polarity test the polarity test can be completed with the ttr on power, distribution, and potential transformers. The standard for maintenance testing specifications for electrical power equipment and. The purchase, preparation, assembly, operation and maintenance of transformers represent a large expense to the power system. Power transformer testing swp check this is the latest process zone version before use. Abbs latest development, the trafositetesting mobile test unit is a mobile highvoltage test system for onsite testing of power transformers. How a stepdown transformer works a transformer is an electric induction device, and it only works with alternating current. Testing potential transformers by les warner pca valence and chris werstiuk valence electrical training services llc potential transformers pts are necessary to a power system for metering and protective relaying to convert higher system voltages to lower control voltages that are more practical from. Inspection and test plan reference document acceptance criteria verifying document 1.
The resulting overloads of grid sections can lead to farreaching supply and production failures. Testing of power transformers seems like a similar experience. On smaller drytype transformers, such as the one shown in figure 1, not a lot of time and money is spent on their testing and maintenance. Type test procedure iec, nec, nema, fdf, iso ansi, ci, ipcea iec, nec, nema, fdf, iso ansi, ci, ipcea procedure h r a inspection and test plan for power transformer before manufacturing activity by no.
Power transformers built for reliability and efficiency. The transformer testing methods are broadly divided into two based on where the test is conducted. Nevertheless, for current transformers the ttr test is not used. Ac testing of drytype distribution and power transformers by. The tls100 is a mobile, selfcontained test system designed to be used in the field or in the shop. Power transformers are usually the most vital link in most industrial and commercial electrical systems, and are among the most reliable components in the system. Worldwide, it is the first 3phase system based on a static frequency converter which is especially designed for performing routine and special tests for power transformers. Ansineta mts2015, standard for maintenance testing specifications for electrical power equipment and systems. Importance of transformer processes the way a transformer is handled and the procedures that are used to receive, assemble, process and test the transformer are of fundamental importance to the long life of the transformer. Testing and diagnostics of power transformers brochure 4.
This ms excel spreadsheet is actually detailed instruction for each procedure necessary for correct testing of power transformer. Power transformer testing testing of power transformers 2. For confirming the specifications and performances, an electrical power transformer has to go through a number of testing procedures. Field testing of a power transformer before putting into service 50mva. Power transformer factory test using ieee standards. The preference is that all large power transformers 1 mva be tested with ttr test set. When ac hipot tests are used for routine maintenance, the power transformer can be examined at rated voltage for 3 min instead of testing at 65% of factory test. So for ensuring proper performance of electrical power transformer, voltage and turn ratio test of transformer one of the vital tests. Through careful selection, hierarchal value, and appropriate times of use, today transformer diagnostics generally consists of a comprehensive suite of basic or standard electrical field tests including.
Since transformer losses contribute to as much as 45% of the total losses in power distribution systems, they have been classified as the single major cause of wasted energy in. Use the dmm in ac mode to measure the transformer primary. To test a transformer with a digital multimeter dmm, first turn off power to the circuit. Hence every electrical power transformer must undergo through vector group test of transformer at factory site for ensuring the customer specified vector group of transformer.
123 516 520 1182 53 1289 291 1181 365 847 409 747 1377 619 659 1181 74 298 842 208 348 784 1212 985 51 1341 827 1160 899 999 383 1111 1305 858 1007 923 1251 88 6 1221 603 465 22 620 704